CFD Fire Modelling: When and How to Use It
When does a building need CFD fire modelling? Common triggers, tenability criteria, the PyroSim/FDS workflow and what a good smoke study report includes.
Balvant Jhaveri
1 day ago6 min read


Choosing & Using the Right Fire Extinguisher – Learning Series (Parts 1–10)
A 10-part learning series on choosing and using the right fire extinguisher, from fire classes and agent types to placement, PASS, inspection and testing, based on NFPA 10, IS 2190 and EN 3.
Balvant Jhaveri
1 day ago1 min read


FK-5-1-12 Clean Agent System – Introduction Series (Parts 1–6)
A 6-part introduction to FK-5-1-12 (fluoroketone) total-flooding clean agent systems, based on NFPA 2001 (2025) and ISO 14520-5:2024, with a worked 200 m³ electrical room example.
Balvant Jhaveri
3 days ago1 min read


IG-55 Inert Gas Suppression System – Design & Installation Learning Series (Parts 1–9)
A 9-part learning series on IG-55 (50% nitrogen / 50% argon) total-flooding systems, from first principles to handover and maintenance, built around one worked example: a 328 m³ server room.
Balvant Jhaveri
3 days ago1 min read


Sprinkler System Design & Hydraulic Calculation – Quick Guide (Parts 1–4)
A 4-part Fire & Smoke Systems quick guide to sprinkler design, from the basic formulas to a fully worked hydraulic calculation, based on NFPA 13 (2022).
Balvant Jhaveri
5 days ago1 min read


Fire Protection Pipe Colour Codes
A one-page Fire & Smoke Systems quick guide to fire protection pipe colour codes, referencing IS 2379, ASME A13.1 and the UAE Fire Code.
Balvant Jhaveri
5 days ago1 min read


Fire Hydrant Systems
A one-page Fire & Smoke Systems quick guide to fire hydrant systems, referencing NBC 2016, IS 13039 and NFPA 14 & 24.
Balvant Jhaveri
5 days ago1 min read


Fire Hose Reel Systems
A one-page Fire & Smoke Systems quick guide to fire hose reel systems, referencing IS 884, BS EN 671 and NBC 2016.
Balvant Jhaveri
5 days ago1 min read


Sprinkler Types & Selection (NFPA 13)
A one-page Fire & Smoke Systems quick guide to the main sprinkler types and how to select the right one under NFPA 13.
Balvant Jhaveri
5 days ago1 min read


Refuelling from a Fuel Vehicle: NFPA 37 Clause 6.5.4 Explained
NFPA 37 clause 6.5.4 lists additional safety features for fuel supply to engines, but some do not apply when the tank is refilled from a fuel vehicle. This explains which ones and why.
Balvant Jhaveri
5 days ago1 min read


Clean Agent Systems vs Sprinklers: Does a Clean Agent Replace Sprinkler Protection?
A common interpretation is that using a clean agent system instead of sprinklers stops a building from being treated as fully sprinklered. This slide set examines the question and explains…
Balvant Jhaveri
5 days ago1 min read


NFPA 13 vs 13R vs 13D: Key Differences Explained
A side-by-side look at NFPA 13, 13R and 13D using a four- to five-storey townhouse as a case study, to help engineers and developers understand which standard applies and why it matters.
Balvant Jhaveri
5 days ago1 min read


Underground Pedestrian Tunnel or Underground Building? Choosing the Right SBC Section
An underground pedestrian tunnel is not the same as an underground building. This walkthrough compares the relevant SBC 201 provisions and explains which section should be applied.
Balvant Jhaveri
5 days ago1 min read


Sprinkler Spacing Around Vertical Openings: NFPA 13 Minimum and Maximum
An explanation of the minimum and maximum spacing of the closely spaced sprinklers that protect a vertical opening under NFPA 13, and why both limits matter.
Balvant Jhaveri
5 days ago1 min read


Smoke Descent Analysis: An SFPE-Based Approach
How fast does a smoke layer descend in a large space? This slide set walks through a smoke descent analysis based on SFPE methods and how it supports smoke control design.
Balvant Jhaveri
5 days ago1 min read


Can You Paint Over Intumescent Fireproofing? SBC and NFPA Requirements
A topcoat can go over intumescent fireproofing, but only one that is part of, or approved for, the tested and listed coating system. Neither the SBC nor NFPA gives blanket permission for…
Balvant Jhaveri
5 days ago1 min read


Ancillary vs Accessory vs Incidental Spaces: Getting the Classification Right
These three terms are often used as if they meant the same thing, but they do not. This comparison helps fire engineers and architects choose the right classification route before working…
Balvant Jhaveri
5 days ago1 min read


Double-Leaf Fire Doors: Why the Closing Sequence Matters
A fire-rated door keeps a fire compartment intact only when it is fully closed and positively latched. Double-leaf fire doors are common in plant, electrical, mechanical and generator…
Balvant Jhaveri
5 days ago1 min read


Sprinkler Bulb vs Rope: Which Fails First in a Fire?
A simple experiment: when a sprinkler and a rope are exposed to the same fire, which gives way first? A useful illustration of how quickly a glass-bulb sprinkler responds to heat.
Balvant Jhaveri
5 days ago1 min read


Villa and Hotel Villa Car Garages: SBC Requirements
How the Saudi Building Code treats the car garage of a private villa or a hotel villa, including classification and the separation required from the dwelling.
Balvant Jhaveri
5 days ago1 min read